Highlights
More safety – through dynamic
escape route guidance and visual
orientation aids
High availability – thanks to
system redundancy and decen-
tralized storage of control data
and announcements
Phased evacuation – for optimized
use of escape routes
In addition, the interface to the fi re de-
tection and fi re alarm system, which can
be confi gured to be redundant, helps
improve availability. Thanks to this con-
nection, E100 can be reset after activa-
tion via the fi re alarm system control
panel as well. Moreover, system faults
from E100 are reported to the fi re control
panel where they are displayed and
transmitted.
Reliable operation in an emergency –
for maximum system availability
Thanks to a degrade mode, E100 offers
an extremely high degree of system avail-
ability and thus outstanding protection
in case of fi re. In the unlikely event of a
system processor failure, the amplifi ers
are simply triggered directly and an alarm
tone will be sounded. This ensures highly
reliable alarming at any time.
Phased evacuation – for optimized
use of escape routes
E100 allows automatic phased evacua-
tion that’s individually tailored to your
building. This is based on E100’s freely
programmable control logic and digital
signal processing, which permit the
simultaneous transmission of different
signals and announcements to different
parts of the building.
First, people in the immediate danger
zone are instructed to leave the build-
ing, following the signed escape routes.
The adjacent zones are then gradually
evacuated until all occupants from the
endangered areas are safe. That prevents
escape routes from becoming overcrowd-
ed, which – in combination with reassur-
ing announcements – prevents panic.
A phased evacuation reduces crowding of escape routes and stairways, prevents panic and restricts
evacuation to the extent necessary.
Phased evacuation
Fire detection and alarming
The fi re source was recognized by the fi re detector
and forwarded to the fi re control panel, which in
turn triggers the voice alarm system.
Evacuation
“A re has been reported in this building. Please
leave the building immediately.”
Alert
”A re has been reported in this building. Please
remain calm and wait for further instructions.”